Kelvinator JS4BD030KB Installationsanleitung

Stöbern Sie online oder laden Sie Installationsanleitung nach Split-System-Klimaanlagen Kelvinator JS4BD030KB herunter. Kelvinator JS4BD030KB Installation Guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
SPLIT SYSTEM AIR CONDITIONER
INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY INFORMATION ................. 2
AIR CONDITIONER INSTALLATION ....................3
General Information .............................................. 3
Before You Install this Unit .....................................3
Locating the Air conditioner...................................3
Packaging Removal .............................................. 3
Ground Level .........................................................3
Roof Mount............................................................3
Connecting Refrigerant Tubing between the
Indoor & Outdoor Unit ........................................... 4
ELECTRICAL WIRING ...........................................4
Pre - Electrical Checklist ....................................... 4
Line Voltage ...........................................................4
Comfort Alert
TM
Diagnostics Module ..................... 5
24VAC Power Wiring ........................................... 5
Thermostat Demand Wiring ................................ 5
Interpreting the Diagnostic LED’s ....................... 5
LED Description .................................................. 6
Grounding ............................................................. 6
Thermostat Low / Voltage Connections ................. 6
AIR CONDITIONER MAINTENANCE ....................6
STARTUP & ADJUSTMENTS ...............................7
Pre - Start Checklist .............................................. 7
Start-up Procedures .............................................. 7
Air Circulation - Indoor Blower .............................. 7
System Cooling ..................................................... 7
System Heating ..................................................... 7
DO NOT DESTROY. PLEASE READ CAREFULLY & KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
IMPORTANT
ATTENTION INSTALLERS:
It is your responsibility to know this product better than your customer. This includes
being able to install the product according to strict safety guidelines and instructing
the customer on how to operate and maintain the equipment for the life of the product.
Safety should always be the deciding factor when installing this product and using
common sense plays an important role as well. Pay attention to all safety warnings and
any other special notes highlighted in the manual. Improper installation of the furnace
or failure to follow safety warnings could result in serious injury, death, or property
damage.
These instructions are primarily intended to assist qualified individuals experienced in
the proper installation of this appliance. Some local codes require licensed installation/
service personnel for this type of equipment. Please read all instructions carefully
before starting the installation. Return these instructions to the customer’s package
for future reference.
S4BD SERIES - 018, 024, 030, 036, 042, 048, & 060 (1.5, 2, 2.5, 3, 3.5, 4, & 5 Ton)
13 SEER, SINGLE PHASE MODELS
Refrigerant Charging ............................................. 7
Charging the Unit in AC Mode with
Outdoor Temperatures Above 55° F ......................8
Application Notes for Using Charging Charts ....... 8
S4BD CHARGING CHARTS .................................8
Figure 3. Charging Chart for 1.5 Ton Units .......... 8
Figure 4. Charging Chart for 2 Ton Units ............. 9
Figure 5. Charging Chart for 2.5 Ton Units .......... 9
Figure 6. Charging Chart for 3 Ton Units ........... 10
Figure 7. Charging Chart for 3.5 Ton Units ........ 10
Figure 8. Charging Chart for 4 Ton Units ........... 11
Figure 9. Charging Chart for 5 Ton Units ........... 11
S4BD CHARGING TABLES ................................. 12
Table 3. Charging Table for 1.5 Ton Units .......... 12
Table 4. Charging Table for 2 Ton Units ............. 12
Table 5. Charging Table for 2.5 Ton Units .......... 13
Table 6. Charging Table for 3 Ton Units ............. 13
Table 7. Charging Table for 3.5 Ton Units .......... 14
Table 8. Charging Table for 4 Ton Units ............. 14
Table 9. Charging Table for 5 Ton Units ............. 15
ELECTRICAL DIAGRAMS & TABLES ................ 16
Figure 10. W.D., Single Phase (1.5 - 5 Ton) ...... 16
Table 10. Comfort Alert LED Diagnostics .......... 17
Table 11. Module Wiring Troubleshooting .......... 18
INSTALL. / PERFORMANCE CHECKLIST ......... 20
REPLACEMENT PARTS ...................................... 20
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - IMPORTANT

SPLIT SYSTEM AIR CONDITIONERINSTALLATION INSTRUCTIONSIMPORTANT SAFETY INFORMATION ... 2AIR CONDITIONER INSTALLATION ...

Seite 2 - CAUTION:

1025027530032535037540042545047550052555057560075 80 85 90 95 100 105 110115 120 125 130Liquid Temperature (F)Liquid Pressure (psig)135Remove refriger

Seite 3 - AIR CONDITIONER INSTALLATION

11NOTE: Do not add or remove refrigerant if pressure reading is between the curves.Figure 8. Charging Chart for S4BD-048 Series (4 Ton Units) - TXV Ma

Seite 4

12Table 3. Charging Table for S4BD-018 Series (1.5 Ton Units) - Orifice MatchesSuct.Press.OUTDOOR TEMPERATURE (°F)70 75 80 85 90 95 100 105Liq.Press.Di

Seite 5

13Table 5. Charging Table for S4BD-030 Series (2.5 Ton Units) - Orifice MatchesSuct.Press.OUTDOOR TEMPERATURE (°F)70 75 80 85 90 95 100 105Liq.Press.Di

Seite 6

14Table 7. Charging Table for S4BD-042 Series (3.5 Ton Units) - Orifice MatchesSuct.Press.OUTDOOR TEMPERATURE (°F)70 75 80 85 90 95 100 105Liq.Press.Di

Seite 7

15Suct.Press.OUTDOOR TEMPERATURE (°F)70 75 80 85 90 95 100 105Liq.Press.Dis.Temp.Liq.Press.Dis.Temp.Liq.Press.Dis.Temp.Liq.Press.Dis.Temp.Liq.Press.Di

Seite 8

16Figure 10. Wiring Diagram for S4BD Single Phase Models(1.5, 2, 2.5, 3, 3.5, 4, & 5 Ton Units)Single Phase1. Couper le courant avant de faire let

Seite 9

17COMFORT ALERT TROUBLESHOOTINGTable 10. LED DiagnosticsStatus LED Status LED Description Status LED Troubleshooting InformationPOWER(Green LED)Module

Seite 10 - Liquid Pressure (psig)

18COMFORT ALERT TROUBLESHOOTING - CONTINUEDTable 10. LED Diagnostics - ContinuedStatus LED Status LED Description Status LED Troubleshooting Informat

Seite 12

2 WARNING:The information listed below must be followed during the installation, service, and operation of this unit. Unqualified individuals should no

Seite 13

INSTALLATION / PERFORMANCE CHECK LISTELECTRICAL SYSTEMElectrical connections tight? YES NOLine voltage polarity correct? YES NORated Voltage: ________

Seite 14

3AIR CONDITIONER INSTALLATIONGeneral InformationThe S4BD series air conditioner is designed only for outdoor rooftop or ground level installations. Th

Seite 15

4Connecting Refrigerant Tubing Between the Indoor & Outdoor Unit CAUTION:When servicing, cover or seal openings to minimize the exposure of the re

Seite 16 - ¢710388B¤

5• Providepowersupplyfortheunitinaccordancewiththeunit wiring diagram, and the unit rating plate. Connect the line-voltage leads to the ter

Seite 17 - COMFORT ALERT TROUBLESHOOTING

6NOTES:• Factoryinstalled moduleshave different thermostatdemand signal wiring. Always follow manufacturer wiring instructions when replacing t

Seite 18

7Refrigerant Charging WARNING:S4BD Split System Air Conditioners are shipped charged with R410A refrigerant and ready for installation. If repairs mak

Seite 19

8Charging the Unit in AC mode at outdoor temperatures above55°Fforoptimizedsub-coolingof10°F-12°F.1. With the system operating at steady-st

Seite 20 - REPLACEMENT PARTS

9NOTE: Do not add or remove refrigerant if pressure reading is between the curves.Figure 4. Charging Chart for S4BD-024 Series (2 Ton Units) - TXV Mat

Kommentare zu diesen Handbüchern